Customization: | Available |
---|---|
Accuracy: | ±0.2-0.5% |
Main Application: | Water, Wastewater, Diesel Fuel, Fuel Oil, Conductive Liquid |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Electromagnetic flow meters are applicable for all
conductive liquids, such as:Domestic water, industrial water, raw water, ground water, urban sewage, industrial wastewater, the
processed neutral pulp, pulp slurry, etc
Name | magnetic Flow Meter |
Nominal diameter | 15-2000mm |
Maximum flow speed | 15m/s |
Accuracy | ±0.5%, ±0.2% |
Medium conductivity | ≥5uS/cm,Actual conductivity≥30uS/cm |
Nominal pressure | 4.0MPa(DN0-150) |
1.6MPa(DN200-600) | |
1.0MPa(DN700-1200) | |
0.6MPa(DN400-2000) | |
Output signal | 4-20mA;Pulse |
Supply voltage | 110/220VAC(100-240VAC),50Hz/60Hz;24VDC ±10% |
Electrode material | stainless steel coated with carbonized tungsten, |
stainless steel containing Mo | |
Hastelloy C | |
Hastelloy B | |
Titanium | |
Tantalum | |
Platinum-iridium alloy. | |
Communication | RS-485,Support standard Modbus-RTU protocol;GPRS |
Number of electrodes | Standard configuration 3-4 electrodes (two measuring electrodes plus a grounding electrode) |
Grounding ring | Stainless steel |
Flange material | Carbon steel |
Flange material | Standard carbon steel and stainless steel are needed to be customized |
Housing material | Standard carbon steel and stainless steel are needed to be customized |
Level of protection | Remote type flow meter IP68 |
Compact type flow meter IP65 | |
Cable length | 10m standard configuration connecting line, optional 15m, 20m, 25m, 30m. (Remote type) |
Maximum fluid temperature: | Compact type: 60ºC |
Remote type: 150ºC | |
Neoprene 80ºC; 120ºC | |
Polyurethane 70ºC |